• Skip to site navigation
  • Skip to content
Gallagher
  • News
  • Events
  • Partner Support
  • Contact Us
  • Gallagher Group Sites

  • Animal Management

  • Corporate

  • Fuel Systems

  • Solutions
  • Products
  • Services
  • Sales & Support
  • Customer Networks
  • About Us
Security

Home » Search By Tag

Search By Tag

  • All
  • Software Maintenance
  • Casino / Gaming
  • Education - Tertiary
  • Access Control
  • Perimeter Security
  • Airports
  • Auto Salvage
  • Ports
  • Mining and Resources
  • Residential
  • Small - Medium Business
  • Education - Schools
  • Finance
  • High Security
  • Telecommunications
  • Storage
  • Critical Infrastructure
  • Correctional Facilities
  • Banks
  • Enterprise
  • Transport/Logistics
  • Government
  • Elevator
  • Imaging
  • Wireless & Data on Card Readers
  • Time and Attendance
  • People Logistics and Rostering
  • Occupational Health & Safety (OH&S)
  • Intercom
  • Integration Platform
  • Command and Control
  • Electronic Key Cabinet
  • Duress Alarm
  • Carpark Management
  • Card Printers
  • Gallagher System Key Strengths
  • Gallagher Prox Readers
  • Long Range Readers
  • Alarms Management
  • Biometric Readers
  • Wireless Readers
  • High Level Integration
  • Optional Features
  • Case Studies
  • Corporate
  • About Us
  • 7.00 Overview
  • Alarm Management
  • Cardholder Management
  • Site Monitoring
  • Challenge
  • Software Upgrades
  • RFID
  • Gallagher T Series Readers
  • Fuel Pump
  • Security
Close

Gallagher Code of Practice

Read more

All Gallagher accredited dealers agree to commit to design, install and maintain Gallagher security electric fence systems in accordance with the Gallagher Code of Practice and Minimum Quality Standards. These Gallagher standards exceed the requirements of all national and international standards for the safety and application of electric fence systems.

Close

System Scalability and Flexibility

Read more

The Gallagher system is scalable from zero doors, such as a perimeter security only solution, to full global, multi-site systems with centralised command and control. Our scalable ‘per door’ pricing (access and alarms capability are core), means that customers need only purchase what they require.

Customisations can alternatively be created to meet your specific requirements. Read more about our Professional Services.

All combinations of Gallagher’s Command Centre software feature and product offering are available for any size sites. The system provides the ability to integrate with Wiegand access control readers or devices, minimising hardware redundancy and unnecessary cost.

Want to find out more about this...

Request more information

Request for more information

- -
Cancel
  • Compatible Products

    Gallagher’s open system architecture facilitates interfacing with a range of complementary products, creating significant business value. Read more

  • System for the Future

    Our strategy to become leader in provision and distribution of security systems is underpinned by our commitment to ongoing development. Read more

  • Software Maintenance

    Read more

  • Core Integration Platform Interfaces and Datasharing

    Read more

Close

IT Compatibility

Read more

The database options are Microsoft SQL 2005 Standard or Express and SQL 2008 Standard or Express depending on the system requirements.

Renowned for its data integrity and performance, Microsoft SQL is a commonly specified database used globally in a range of applications. It is easy to integrate and share selected data held in Gallagher’s Command Centre with other systems using the SQL Server database.

Gallagher is a partner to Microsoft and a member of OPC Foundation.

Command Centre features:

• 64 bit operating system support

• MS Windows 7 Professional / Ultimate

• Microsoft Windows 2003 SP2, 2008 SP2, 2008 Server R2

Command and Control Platform: Command Centre Software

Gallagher field Controllers (6000, 3000 and 5000GL) are fully network (TCP/IP) capable and can communicate peer-to-peer, facilitating system flexibility and redundancy and protecting against malicious network attacks. Controller software is downloadable.

Gallagher Controller 6000

Gallagher Controller 3000

Gallagher Controller 5000GL

Integrity of data protection

  • Products

    Large and small organizations throughout the world trust Gallagher to deliver world-class thinking that addresses their most significant issues of security and risk management, personnel... Read more

Close

Distributed Intelligence and Data Storage

Read more

If a site experiences network communication problems, distributed intelligence allows for continued operation of access control and alarms management. The relevant fields of the cardholder database, alarm configuration and security parameters are downloaded to the Controllers resulting in instant access and alarm control decisions.

All events and alarms are date and time-stamped before being sent to the Command Centre.

Each Controller 3000 is capable of buffering events should communications fail. These events are then automatically sent to the Command Centre when communications are re-established.

True peer-to-peer communications between Controllers facilitates system flexibility, redundancy and protection against malicious network attacks.

Gallagher Controller 6000

Gallagher Controller 3000

Gallagher Controller 5000GL

REDUNDANT ALARM DIALLING

The Gallagher Dialler facilitates communications between the Gallagher Command Centre Server and Controllers that, once configured, operates independently of the Command Centre.

The Gallagher system facilitates off-site monitoring by transmitting alarms to a remote monitoring station using industry standard Contact ID data format. A monitoring station is informed immediately if there is a breach of security, enabling the dispatch of security guards to re-secure your business.

The Gallagher Dialler, connecting to the Gallagher Controller 6000 and 3000, is the hardware device that performs the Contact ID data transmission. An on-board connection is provided for the Gallagher Dialler 5000GL.

REDUNDANT ALARM CONTROL

The Gallagher Remote Arming Terminal supports multiple controllers that, once configured, operate independently of the Gallagher Command Centre.

Close

Integrity of Data Protection

Read more

Encrypted Communications

Gallagher’s system communications offers 128 bit Secure Socket Layer (SSL) encryption of data communicated over the network (although higher levels are available). This includes communications between the Gallagher Command Centre server and Gallagher Controllers and peer-to-peer Controller communications.

IP-based, encrypted network communications between the Gallagher  Command Centre software and Gallagher field Controllers (6000, 3000, 5000GL) uses an industry-leading level of encryption of up to 256 bit AES symmetric encryption and RSA-1024 bit authentication.

Gallagher Field Controllers (6000, 3000 and 5000GL)

Gallagher Controllers make all the access decisions in the field – a distributed intelligence that enables uninterrupted system operation even when the server is offline.

Features and Benefits:

• Fully network (TCP/IP) capable

• True peer-to-peer communications between Controllers facilitate system flexibility, redundancy and protection against malicious network attacks

• Controllers communicate with each other via peer-to-peer communications over a LAN/WAN using TCP/IP for monitoring, back-up and control, a significant feature that provides extensive flexibility and efficient system configuration

• Feature downloadable Controller software.

Access Control Readers

Access card reading is protected by Cardax IV data format with only licensed individuals able to create cards for sites. Issue levels are also supported.

Features and Benefits:

• Custom site keys are supported when used with MIFARE Plus and MIFARE DESFire EV1 cards

• ‘Heartbeat’ monitoring ensures reader status can be monitored in real time and status reports can be generated. An alarm is raised at the Command Centre workstation if the reader stops communicating with the field Controller

• MIFARE Enhanced Security (MES) options prevent and detect cloning attempts

• Gallagher readers use the proven Cardax IV reader communications delivering enhanced reader security through encryption and monitoring of the data between the reader and Controller.

Gallagher’s facility code management delivers unique facility code issue worldwide.

With Cardax IV proprietary format, enhanced data protection is achieved via:

• Encoding of issue level and region code in addition to facility code and card number, providing unique card data across global card databases

• Eight bit error detection protocol, ensuring that the reader correctly identifies the card being presented.


Supported Card Technologies

Gallagher readers support multiple card technologies including 125 kHz, MIFARE Classic, MIFARE Plus and MIFARE DESFire EV1.

MIFARE DESFire EV1 format implements the strong AES 128 bit data encryption standard to ensure data security. Custom site keys are supported when used with MIFARE Plus and MIFARE DESFire EV1 cards. MIFARE Enhanced Security (MES) options are available to counter card-cloning attempts. Find out more about which card and reader technologies are right for your site.

System Division (partitioning) structure allows multiple tenants to operate or manage their own individual systems, operating within a larger multi-tenanted sites.

Want to find out more about this...

Request more information

Request for more information

- -
Cancel
Close

System for the Future

Read more

Our strategy to become a world leader in the provision and distribution of security systems is underpinned by our commitment to the ongoing development and manufacture of quality solutions.

Gallagher’s Command Centre security integration platform is an evolutionary product and the result of heavy investment in R&D. Having developed four generations of access control hardware over 25 years, we are committed to providing upgrade paths and facilitating stage technology migration at our customers’ pace. Gallagher Command Centre software is therefore also backward compatible.

We’re focused on developing the Gallagher platform over a long period of time with software enhancements, interfaces and new hardware, with Software Maintenance available for ongoing upgrades to ensure that our customers benefit from the latest software developments.

Innovation

Want to find out more about this...

Request more information

Request for more information

- -
Cancel
Show more results

Latest News All news

  • Intersec Dubai

    01/02/2012

    Gallagher Asia/Middle East sales team welcomed 2012 with a successful exhibit at the 14th annual... Read more

  • Challenging but exciting year ahead

    30/01/2012

    Gallagher, is preparing itself for a challenging, but exciting year as the company's technology creates... Read more

Upcoming Events All events

  • Tertiary Education Security Network (TESN)

    07/06/2012

    Venue: La Trobe University, Melbourne Read more

  • Vakbeurs Gebouwbeheer (Building Management Exhibition)

    08/06/2012

    Venue: Jaarbeurs Utrecht Read more

Gallagher Group

  • Gallagher Group Ltd is a privately owned, global technology company with expertise in security, animal management and fuel pump systems.

    Gallagher Group

Our Other Business Units

  • Animal Management
  • Fuel Systems
  • Contract Manufacturing
  • Careers
  • Contact Us
  • Privacy Statement
  • Site Map
  • Copyright © Gallagher Group Limited